{"id":6997,"date":"2019-07-10T08:38:00","date_gmt":"2019-07-10T06:38:00","guid":{"rendered":"https:\/\/www.comisa.it\/nuova-valvola-a-sfera-137\/"},"modified":"2021-10-27T10:14:05","modified_gmt":"2021-10-27T08:14:05","slug":"new-ball-valve-137","status":"publish","type":"post","link":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137","title":{"rendered":"NEW BALL VALVE 137"},"content":{"rendered":"\r\n<p>The new Comisa valve represents innovation and safety thanks to its performance characteristics.<\/p>\r\n<h3>ANTI LEGIONELLA<\/h3>\r\n<p>Legionellosis is a <strong>lung infection<\/strong> caused by the bacterium Legionella pneumophila and is transmitted to humans through the inhalation of contaminated water particles.<\/p>\r\n<p>Currently infections mainly derive from the contamination of <strong>water distribution<\/strong>systems such as: shower, air conditioners, iron, water systems etc. Legionella can be avoided through the choice of suitable <strong>plumbing products<\/strong>.<\/p>\r\n<p>Like the <strong>137 Comisa ball valve<\/strong> which has a perforated sphere and contrary to what happens in traditional systems, when the valve is in a totally open position, the continuous rinsing prevents stagnant water and the proliferation of bacteria.<\/p>\r\n<h3>ANTI-FROST<\/h3>\r\n<p>The 137 Comisa ball valve has a <strong>perforated ball<\/strong> that always keeps the body chamber in communication with the valve passage.<\/p>\r\n<p>This <strong>prevents <\/strong>the possible <strong>formation of frost<\/strong> from generating strong pressure on the internal walls causing them to break as happens in many other types of valves.<\/p>\r\n<h3>DVGW and DRINKING WATER<\/h3>\r\n<p><strong>DVGW<\/strong> is the German acronym of &#8220;Deutscher Verein des Gas und Wasserfaches e. V.-Technisch-wissenschaftlicher Verein&#8221;; that is the German technical and scientific association for gas and water.<\/p>\r\n<p>The 137 Comisa valve complies with the <strong>EN13828<\/strong> standard and the <strong>DVGW W570-1<\/strong>worksheet, the latter regulates the requirements regarding <strong>hygiene and materials<\/strong>, defines <strong>self-monitoring<\/strong> and third-party monitoring, as well as <strong>product-specific national requirements<\/strong>.<\/p>\r\n<p><em><u><a href=\"https:\/\/comisa.it\/en\/plumbing-and-heating\/serie-spr\" rel=\"noopener noreferrer nofollow\">Go to the product<\/a><\/u><\/em><\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>The new Comisa valve represents innovation and safety thanks to its performance characteristics. ANTI LEGIONELLA Legionellosis is a lung infection caused by the bacterium Legionella pneumophila and is transmitted to humans through the inhalation of contaminated water particles. Currently infections mainly derive from the contamination of water distributionsystems such as: shower, air conditioners, iron, water [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[460],"tags":[],"class_list":["post-6997","post","type-post","status-publish","format-standard","hentry","category-products"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NEW BALL VALVE 137 - Comisa<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NEW BALL VALVE 137 - Comisa\" \/>\n<meta property=\"og:description\" content=\"The new Comisa valve represents innovation and safety thanks to its performance characteristics. ANTI LEGIONELLA Legionellosis is a lung infection caused by the bacterium Legionella pneumophila and is transmitted to humans through the inhalation of contaminated water particles. Currently infections mainly derive from the contamination of water distributionsystems such as: shower, air conditioners, iron, water [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\" \/>\n<meta property=\"og:site_name\" content=\"Comisa\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/comisaspa\/\" \/>\n<meta property=\"article:published_time\" content=\"2019-07-10T06:38:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-10-27T08:14:05+00:00\" \/>\n<meta name=\"author\" content=\"Mauro Tolla\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mauro Tolla\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\"},\"author\":{\"name\":\"Mauro Tolla\",\"@id\":\"https:\/\/www.comisa.it\/en\/#\/schema\/person\/04fac5911ece25bea5e47bc1c7f7d397\"},\"headline\":\"NEW BALL VALVE 137\",\"datePublished\":\"2019-07-10T06:38:00+00:00\",\"dateModified\":\"2021-10-27T08:14:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\"},\"wordCount\":227,\"publisher\":{\"@id\":\"https:\/\/www.comisa.it\/en\/#organization\"},\"articleSection\":[\"Products\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\",\"url\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\",\"name\":\"NEW BALL VALVE 137 - Comisa\",\"isPartOf\":{\"@id\":\"https:\/\/www.comisa.it\/en\/#website\"},\"datePublished\":\"2019-07-10T06:38:00+00:00\",\"dateModified\":\"2021-10-27T08:14:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.comisa.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NEW BALL VALVE 137\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.comisa.it\/en\/#website\",\"url\":\"https:\/\/www.comisa.it\/en\/\",\"name\":\"Comisa\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.comisa.it\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.comisa.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.comisa.it\/en\/#organization\",\"name\":\"Comisa\",\"url\":\"https:\/\/www.comisa.it\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.comisa.it\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.comisa.it\/wp-content\/uploads\/2021\/09\/logo-comisa@2x.png\",\"contentUrl\":\"https:\/\/www.comisa.it\/wp-content\/uploads\/2021\/09\/logo-comisa@2x.png\",\"width\":320,\"height\":68,\"caption\":\"Comisa\"},\"image\":{\"@id\":\"https:\/\/www.comisa.it\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/comisaspa\/\",\"https:\/\/www.linkedin.com\/company\/comisa\/\",\"https:\/\/www.youtube.com\/user\/comisagroup\",\"https:\/\/www.instagram.com\/comisa_spa\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.comisa.it\/en\/#\/schema\/person\/04fac5911ece25bea5e47bc1c7f7d397\",\"name\":\"Mauro Tolla\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.comisa.it\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ea87253a50d5fe184a83ad9c7b788cb90862baebb71b26c7488f51ab66c50012?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ea87253a50d5fe184a83ad9c7b788cb90862baebb71b26c7488f51ab66c50012?s=96&d=mm&r=g\",\"caption\":\"Mauro Tolla\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NEW BALL VALVE 137 - Comisa","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137\/","og_locale":"en_US","og_type":"article","og_title":"NEW BALL VALVE 137 - Comisa","og_description":"The new Comisa valve represents innovation and safety thanks to its performance characteristics. ANTI LEGIONELLA Legionellosis is a lung infection caused by the bacterium Legionella pneumophila and is transmitted to humans through the inhalation of contaminated water particles. Currently infections mainly derive from the contamination of water distributionsystems such as: shower, air conditioners, iron, water [&hellip;]","og_url":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137","og_site_name":"Comisa","article_publisher":"https:\/\/www.facebook.com\/comisaspa\/","article_published_time":"2019-07-10T06:38:00+00:00","article_modified_time":"2021-10-27T08:14:05+00:00","author":"Mauro Tolla","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Mauro Tolla","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137#article","isPartOf":{"@id":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137"},"author":{"name":"Mauro Tolla","@id":"https:\/\/www.comisa.it\/en\/#\/schema\/person\/04fac5911ece25bea5e47bc1c7f7d397"},"headline":"NEW BALL VALVE 137","datePublished":"2019-07-10T06:38:00+00:00","dateModified":"2021-10-27T08:14:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137"},"wordCount":227,"publisher":{"@id":"https:\/\/www.comisa.it\/en\/#organization"},"articleSection":["Products"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137","url":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137","name":"NEW BALL VALVE 137 - Comisa","isPartOf":{"@id":"https:\/\/www.comisa.it\/en\/#website"},"datePublished":"2019-07-10T06:38:00+00:00","dateModified":"2021-10-27T08:14:05+00:00","breadcrumb":{"@id":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.comisa.it\/en\/products\/new-ball-valve-137#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.comisa.it\/en\/"},{"@type":"ListItem","position":2,"name":"NEW BALL VALVE 137"}]},{"@type":"WebSite","@id":"https:\/\/www.comisa.it\/en\/#website","url":"https:\/\/www.comisa.it\/en\/","name":"Comisa","description":"","publisher":{"@id":"https:\/\/www.comisa.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.comisa.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.comisa.it\/en\/#organization","name":"Comisa","url":"https:\/\/www.comisa.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.comisa.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.comisa.it\/wp-content\/uploads\/2021\/09\/logo-comisa@2x.png","contentUrl":"https:\/\/www.comisa.it\/wp-content\/uploads\/2021\/09\/logo-comisa@2x.png","width":320,"height":68,"caption":"Comisa"},"image":{"@id":"https:\/\/www.comisa.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/comisaspa\/","https:\/\/www.linkedin.com\/company\/comisa\/","https:\/\/www.youtube.com\/user\/comisagroup","https:\/\/www.instagram.com\/comisa_spa\/"]},{"@type":"Person","@id":"https:\/\/www.comisa.it\/en\/#\/schema\/person\/04fac5911ece25bea5e47bc1c7f7d397","name":"Mauro Tolla","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.comisa.it\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ea87253a50d5fe184a83ad9c7b788cb90862baebb71b26c7488f51ab66c50012?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ea87253a50d5fe184a83ad9c7b788cb90862baebb71b26c7488f51ab66c50012?s=96&d=mm&r=g","caption":"Mauro Tolla"}}]}},"acf":[],"_links":{"self":[{"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/posts\/6997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/comments?post=6997"}],"version-history":[{"count":2,"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/posts\/6997\/revisions"}],"predecessor-version":[{"id":7002,"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/posts\/6997\/revisions\/7002"}],"wp:attachment":[{"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/media?parent=6997"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/categories?post=6997"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.comisa.it\/en\/wp-json\/wp\/v2\/tags?post=6997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}